19.2. Usage
19.2. Usage
19.2. Usage
19.2. Usage of the Relay to Interrupt the ATX
of the Relay to Interrupt the ATX
of the Relay to Interrupt the ATX
of the Relay to Interrupt the ATX----control
control
control
control----line
line
line
line
If the relay output of the aquaero is integrated into the ATX-control-line
of the PSU, the standby-power-supply must be connected. Suitable ca-
bles for both functions are available as special accessories.
To start the computer for the first time, the relay must be switched on
manually once. This is done in the menu "Relay Parameters".
19.3.
19.3.
19.3.
19.3. Starting of the PC when using the Standby
Starting of the PC when using the Standby
Starting of the PC when using the Standby
Starting of the PC when using the Standby----Power
Power
Power
Power----Supply
Supply
Supply
Supply
When using the standby power supply on the aquaero, a menu shows
up when the PSU is switched on. In this menu you can choose the usage
of the relay. Depending on the configuration you need to select the
„ATX-Break-Line“ or „Power-Switch“ and confirm the selection by press-
ing the „set/mode“ button. When using the ATX-Break-Line, the PC may
now be switched on via the main power button. When the relay is used
as a power switch, you can start your PC by pressing the „set/mode“
button. This menu shows up after every cut in the power supply.
Please note: If the PC starts up im
Please note: If the PC starts up im
Please note: If the PC starts up im
Please note: If the PC starts up immediately after pressing the
mediately after pressing the
mediately after pressing the
mediately after pressing the
“set/mode” button when using the ATX
“set/mode” button when using the ATX
“set/mode” button when using the ATX
“set/mode” button when using the ATX----Break
Break
Break
Break----Line, „Restart after
Line, „Restart after
Line, „Restart after
Line, „Restart after AC
AC
AC
AC
power loss“ (or similar) is most likely activated in the computer bios
power loss“ (or similar) is most likely activated in the computer bios
power loss“ (or similar) is most likely activated in the computer bios
power loss“ (or similar) is most likely activated in the computer bios....
19.4. Restrictions of the Emergency Shutdown
19.4. Restrictions of the Emergency Shutdown
19.4. Restrictions of the Emergency Shutdown
19.4. Restrictions of the Emergency Shutdown
The emergency shutdown function, if connected and configured prop-
erly, can prevent damages to your hardware. However no protection
can be a hundred percent. We therefore deny any liability for damages
We therefore deny any liability for damages
We therefore deny any liability for damages
We therefore deny any liability for damages
that are created by or in spite of using this function.
that are created by or in spite of using this function.
that are created by or in spite of using this function.
that are created by or in spite of using this function. Especially with the
connection as a power button on the mainboard the emergency shut-
down may remain unsuccessful!
19.5. Flow Alarm and the aquastream
19.5. Flow Alarm and the aquastream
19.5. Flow Alarm and the aquastream
19.5. Flow Alarm and the aquastream----pump
pump
pump
pump
If an aquastream-pump with a firmware-revision 1.04 or higher is con-
nected to the aquaero via the separately available 10-pin cable and an
alarm is triggered by the flow sensor, the pump is automatically switched
to the standard mode and the user-frequency is reset to the default
value. This change is stored permanently in the pump controller. The
pump frequency can be readjusted again manually in the periphery