AQUAERO
- 24 -
Aqua Computer GmbH & Co. KG
© 2004-2009
Gelliehäuser Str. 1, 37130 Gleichen, Germany
The setting „Fan4= FlowSensor2“ configures the fan-output 4 to be
used with a second flow sensor. In the “Fan Parameters” menu the set-
ting for fan 4 must be set to manual and adjusted to 100% output. (see
also 10.
10.
10.
10. Menu
Menu
Menu
Menu "Fan
"Fan
"Fan
"Fan Parameters"
Parameters"
Parameters"
Parameters"). The name for fan 4 will be used for
the flow sensor. If preferred you can change the name to “FlowSens.2”
for instance. Also the calibration factor for fan 4 must be adjusted to the
number of impulses per liter. Sensors distributed by us therefore have to
be set to 509 Imp/U.
9.7. Back
9.7. Back
9.7. Back
9.7. Back
Leaves the submenu and returns to "Settings".