AQUAERO
- 44 -
Aqua Computer GmbH & Co. KG
© 2004-2009
Gelliehäuser Str. 1, 37130 Gleichen, Germany
Now enter the following values in the fan parameters for fans 1 and 2:
Sensor 1 (Auto): Sensor 1
Regulation options: Fixed
Result:
When a temperature of 35 °C is measured at sensor 1, the fans 1 and 2
are switched on at a low speed. The fan speed is regulated so that the
temperature is held steadily at 35 °C if possible. If the temperature rises
further, the fans are regulated up to their maximum performance. If the
temperature drops, the fans are slowed down.
18.3. Temperature
18.3. Temperature
18.3. Temperature
18.3. Temperature----dependent Illumination
dependent Illumination
dependent Illumination
dependent Illumination
Example configuration:
Sensor 1 measures a temperature
A red LED is connected to the LED-connector 1 of the aquaero
A green LED is connected to the LED-connector 2 of the aquaero
Solution:
Enter the following values in the sensor parameters for sensor 1:
Start-up threshold: 30 °C
Full load threshold: 50 °C
Now enter the following values in the LED parameters:
LED 1:
Sensor 1 (Auto): Sensor 1
Lighter/Darker: Brighter if warmer
LED 2:
Sensor 1 (Auto): Sensor 1
Lighter/Darker: Darker if warmer
Result:
With climbing temperatures at the sensor 1 the red LED will get brighter
while the green LED gets darker. Below 30 °C at sensor 1 only the green
LED and above 50 °C only the red LED will be lit. Suitable to illuminate
the reservoir container of a water-cooling system, which changes the
color temperature-dependently from green to yellow to red.