![Aqua Computer AQUAERO 4.00 Owner'S Manual Download Page 21](http://html1.mh-extra.com/html/aqua-computer/aquaero-4-00/aquaero-4-00_owners-manual_2958139021.webp)
MANUAL
© 2004-2009
Aqua Computer GmbH & Co. KG
- 21 -
Gelliehäuser Str. 1, 37130 Gleichen, Germany
Regulator option „linear“ or „progressive“:
Simply put, the hysteresis is the difference between the start-up and
shutdown temperature for the fans. A frequent start-up and shutdown of
the fans is therefore prevented if the current temperature fluctuates
around the start-up temperature. Should the fans be turned on and off
in short intervals you should increase this value.
Regulator option „target value“:
If the fan is regulated via the target temperature, the hysteresis is the
value which is in the tolerable area in which the fan is not adjusted, an
approved regulator error close to the target value if you will.
If for instance a target value of 35°C and a hysteresis of 1°C is set, then
the rpm of the fan is only adjusted when the temperature rises above
36°C or drops below 34°C.
Adjustable in 0,5°C steps from 0,0°C to 25,0°C. Default setting is
0,0°C.
8.6. Target Temp.
8.6. Target Temp.
8.6. Target Temp.
8.6. Target Temp.
Enter the temperature in °C here, at which the fan should become ac-
tive. The assigned fan will be switched on and, if technically possible,
will regulate a constant target temperature. If the temperature drops be-
low the target temperature, the fan is slowed down.
Adjustable in 0,5°C - steps from 0,0°C to 100,0°C. Default setting is
30,0°C.
8.7. Calibration Offset
8.7. Calibration Offset
8.7. Calibration Offset
8.7. Calibration Offset
Professional function to calibrate the temperature sensors. Standard
value is zero and should not be altered in the normal case. An adjust-
ment may become necessary if sensors of other manufacturers are used.
Internal formula for the temperature calculation, see 8.8. Calibration
Factor.
8.8. Calibration Factor
8.8. Calibration Factor
8.8. Calibration Factor
8.8. Calibration Factor
Professional function to calibrate the temperature sensors. Standard
value is zero and should not be altered in the normal case. An adjust-