7. Device Settings
7. Device Settings
7. Device Settings
7. Device Settings
7.1. Basic operation
7.1. Basic operation
7.1. Basic operation
7.1. Basic operation
In the normal display operation, you can enter the configuration menu
by pressing the button "set/mode" once. In the configuration menu, you
can select individual entries by pressing the "up" and "down" buttons and
then pressing the "set/mode" button. Basically the menu contains two
different entry types:
-
Submenus are marked with a small arrow „
“
in front of the name
of the entry.
-
Adjustable parameters are marked by a diamond „
“ in front of
the name of the entry.
7.1.1. Definition of Names
7.1.1. Definition of Names
7.1.1. Definition of Names
7.1.1. Definition of Names
The aquaero allows you to define all sensors and fans with user-defined
names. After selecting a corresponding menu entry, the current sensor
name is shown and the cursor blinks on the first letter. By pressing the
buttons "up" and "down" you can now choose the first character, the
characters appear in the following sequence: Capital letters, lower case
letters, space, numbers. When selecting the sign "
", the cursor jumps
back one character in the line.
By pressing the button "set/mode" you confirm the chosen character and
the cursor jumps forward one character in the line. Repeat this process
for all indicated spaces. After the input of the last character in the line
the device will return to the menu.
The sensor names have a predefined length. If you would like to use
shorter names, you must fill the free signs with spaces.
7.1.2. Principle of assigning sensors to fans
7.1.2. Principle of assigning sensors to fans
7.1.2. Principle of assigning sensors to fans
7.1.2. Principle of assigning sensors to fans
In principle with the aquaero, the start-up and max. revolution thresh-
olds for the fan control are assigned to the temperature sensors, not the
fans. This means that these values are adjusted for the corresponding
sensor in the menu and then this completely configured sensor serves as
the guideline for one or two fan/s.
One or two temperature sensors can be assigned to each fan, alterna-
tively each fan can individually also be controlled manually.