ment may become necessary if sensors of other manufacturers are used.
The internally used formula to calculate the temperature is:
237+Offset-(44,15-Factor)*ln(measured value) (Output is value in °C)
8.9. Controller delay
8.9. Controller delay
8.9. Controller delay
8.9. Controller delay
This value is only needed if the corresponding fan is in the target-value
mode.
The controller delay sets the minimum time in seconds after which the
controller is recalculated.
The higher this time, the slower the temperature regulator reacts to
changes in temperature which means that the corresponding fan adjusts
the rpm slowly. For instance when regulating an inert system like the wa-
ter temperature in a cooling system, it would be useful to set this value
to approx. 20 seconds.
This value mainly determines the regulatorial behavior at small tempera-
ture differences, at larger temperature differences the effect from the
regulator factor becomes ostensible.
Default value is 3 seconds.
8.10. Controller factor
8.10. Controller factor
8.10. Controller factor
8.10. Controller factor
This value is only needed if the corresponding fan is in the target-value
mode.
The regulator factor is a multiplier for the temperature difference of the
target-value and causes an immediate adjustment of the rpm of the cor-
responding fan.
The higher this value, the stronger the temperature regulator reacts to
differences in the target value.
Default value is 2.
8.11. Back
8.11. Back
8.11. Back
8.11. Back
Leaves the submenu and returns to “Sensor Parameters”.