Select one of the six temperature sensors from the list by pressing the
"up" and "down" buttons and confirm your selection by pressing the but-
ton "set/mode".
To leave the menu "sensor parameters" choose the entry "back" and
confirm the selection by pressing "set/mode".
8.1. Sensor Name
8.1. Sensor Name
8.1. Sensor Name
8.1. Sensor Name
Enter the name of the sensor that should be shown on the display. After
the selection of this menu entry, the current sensor name is shown and
can be changed. See also 7.1.1. Definition of Names.
8.2. Start
8.2. Start
8.2. Start
8.2. Start----up temp.
up temp.
up temp.
up temp.
Enter the temperature in °C here, at which an assigned fan should start.
Below this temperature, an assigned fan is turned off.
If the option “Minimum Power” is activated, the fan will not be shut
down when the temperature drops below the start-up temp. In this case
the minimum power is held constantly.
8.3. Maximum temp.
8.3. Maximum temp.
8.3. Maximum temp.
8.3. Maximum temp.
Enter the temperature in °C here, at which the assigned fan should run
on max. power. Above this temperature, the assigned fan continues to
run at maximum speed.
8.4. Alarm Temp.
8.4. Alarm Temp.
8.4. Alarm Temp.
8.4. Alarm Temp.
Enter the temperature in °C here, at which the PC-emergency shutdown
should be activated. Works only with additional components,
If you use the relay connector for other functions, you enter the switch
temperature here.
8.5. Hysteresis
8.5. Hysteresis
8.5. Hysteresis
8.5. Hysteresis
Depending on the set regulator option this parameter has the following
effect on the regulated fan: