MANUAL
© 2004-2009
Aqua Computer GmbH & Co. KG
- 45 -
Gelliehäuser Str. 1, 37130 Gleichen, Germany
18.4. Emergency Shutdown of the P
18.4. Emergency Shutdown of the P
18.4. Emergency Shutdown of the P
18.4. Emergency Shutdown of the PC on
C on
C on
C on Temperature Alarm
Temperature Alarm
Temperature Alarm
Temperature Alarm
Example configuration:
Sensor 1 measures a temperature
The relay output is integrated into the ATX-control-line (special accesso-
ries needed)
The standby power supply is connected (special accessories needed)
Solution:
Enter the following values in the sensor parameters for sensor 1:
Alarm threshold: 65 °C
(all other sensors at very high values respectively)
Now enter the following values in the relay parameters:
Alarm-Off: Emergency shutdown on
Alarm-Off Timeout: 10 seconds
Alarm-Events: Temperature alarm: on
Relay-Type: "Make-Contact"
Relay-Usage: ATX-Break-Line
Alarm Switch Length: Switch permanently
Result:
When the temperature climbs to 65 °C and above at sensor 1, a warn-
ing is shown in the display for 10 seconds (Alarm-Off-Timeout). If the
temperature remains at or above 65 °C the PSU is turned off by the re-
lay.
19. Special Notices
19. Special Notices
19. Special Notices
19. Special Notices
19.1. Usage of the Relay as a Power Button on the mainboard
19.1. Usage of the Relay as a Power Button on the mainboard
19.1. Usage of the Relay as a Power Button on the mainboard
19.1. Usage of the Relay as a Power Button on the mainboard
If the relay output of the aquaero is connected to the power button of
the mainboard and is correctly configured, the computer can be
switched on via the buttons of the aquaero. This requires a connected
standby-power-supply (special accessories).