12.4. Relay On/Off
12.4. Relay On/Off
12.4. Relay On/Off
12.4. Relay On/Off
By selecting this menu point, the relay is manually switched on. The
status of the relay may change again for instance when an alarm is trig-
gered or when the timer-function is used. If the relay is integrated into
the ATX-control line of the PSU this function might need to be executed
to start the PC. You can leave the screen by pressing the button
"set/mode" again.
12.5. Relay Usage
12.5. Relay Usage
12.5. Relay Usage
12.5. Relay Usage
Here you can setup the relay according to how you want to use it. De-
pending on the setting the relay is addressed differently to shutdown the
PC in case of an alarm-event. A correct setup in this menu is crucial for
the emergency shutdown function of the PC! If the relay is connected to
the power button connection on the mainboard please select "Power
Button", with the integration into the ATX-control-line of the PSU please
select "ATX-Break-Line".
12.6. Alarm Time
12.6. Alarm Time
12.6. Alarm Time
12.6. Alarm Time
Here you can select how long the relay should be switched in the case
of an alarm. A correct setup in this menu is crucial for the emergency
shutdown function of the PC! If the relay is connected to the power but-
ton connection on the mainboard please select a value of at least four
seconds (default setting is 8 seconds).