18. Example configurations
18. Example configurations
18. Example configurations
18. Example configurations
In the following chapters, some configurations are explained in an ex-
emplary way. The sensors and fan canals used can easily be changed to
meet your actual needs.
18.1. Progressi
18.1. Progressi
18.1. Progressi
18.1. Progressive Regulation of a Fan via a Temperature Sensor
ve Regulation of a Fan via a Temperature Sensor
ve Regulation of a Fan via a Temperature Sensor
ve Regulation of a Fan via a Temperature Sensor
Example configuration:
Sensor 1 measures the CPU-temperature
The CPU-fan is connected to the fan canal 1 of the aquaero
Solution:
Enter the following values in the sensor parameters for sensor 1:
Start-up threshold: 30 °C
Full load threshold: 50 °C
Now enter the following values in the fan parameters for fan 1:
Sensor 1 (Auto): sensor 1
Regulation options: Progressive
Result:
When a temperature of 30 °C is measured at sensor 1, the fan 1 is
switched on at a low speed and is progressively regulated in the tem-
perature area up to 50 °C. Above 50 °C the fan permanently runs at full
speed.
18.2. Regulation of a constant water temperature in a water
18.2. Regulation of a constant water temperature in a water
18.2. Regulation of a constant water temperature in a water
18.2. Regulation of a constant water temperature in a water----cooling
cooling
cooling
cooling
system
system
system
system
Example configuration:
Sensor 1 measures the water temperature
Two radiator fans are connected to the fan canals 1 and 2 of the
aquaero
Solution:
Enter the following values in the sensor parameters for sensor 1:
Target temperature: 35,0 °C