To Genlock to the dedicated input:
NOTE:
All Genlock timings meet broadcast ITU/SMPTE standards.
Front Panel
1.
Enter the
OUTPUTS
menu on the Front Panel interface.
2.
Select
STANDARD OUTPUT
to access the standard output setup menu.
3.
Select
Format
to access the standard output format setup menu.
4.
Select
GENLOCK
to use the Genlock input as a reference to set up the format.
5.
Select
Confirm
to save and apply the new settings.
6.
Wait for the
Format generation in progress
screen to check the new format settings.
7.
Once the setup is complete, press the
EXIT-MENU
button to return to the output setup menu.
TIP:
Go to the output setup menu and select
Genlock Tune
to adjust the vertical and horizontal offsets to apply
to the output signal:
•
Offset H:
Offset in pixels (ratio of 1 line) to apply to the output signal.
•
Offset V:
Offset in lines (ratio of 1 frame) to apply to the output signal.
TIP:
Go to the
OUTPUTS
menu and select
GENLOCK REFERENCE > Overload Detected Format
to specify
the format to use on the Genlock reference input
(SEE: Using the Genlock reference).
Web RCS
1.
Go to the
Setup
menu on the Web RCS interface.
2.
Click on the
OUTPUTS
tab to access the outputs setup page.
3.
In the left side toolbar, select
STANDARD OUTPUT
to access the standard output setup page.
4.
Click on the
Signal
tab to access the output format setup page.