Installation and Setup
37
Epica DGX 32 Instruction Manual
APControl 3.0.1
If you are using APControl 3.0.1, install and open the program. Follow the directions in the setup
wizard. Follow the setup wizard. Manually create the VM (virtual matrix) and specify the number of
inputs and outputs. Open the APControl Launchbar. From the Launchbar menu, select Views / CrossBar
and click on the crosspoints to execute switches.
HyperTerminal
When power is applied to the enclosure, HyperTerminal displays a one-line splash screen followed by
“
Ready
” (FIG. 20). The system is ready to disconnect the factory default switch and to execute a test
switch (see page 38).
If you need to access advanced system information, see “Appendix D – Programmer’s Interface for
System Diagnostics” on page 133.
Note: AMX reserves the right to add to the contents of the splash screen at any time, without notice.
Redundant Power Supply (RPS)
Each enclosure ships with two mutually-redundant (hot-swappable) power supplies.
The Power indicator on the front of the enclosure will illuminate a constant red if a problem occurs with
one of the power supplies. Check the AC and DC LED indicators on the rear of the enclosure directly
above each power receptacle to determine if a power supply is not working.
For additional LED indicator information, see page 36.
Important: A failed power supply should be replaced as soon as possible to maintain the system’s
power redundancy. For replacement information, contact technical support (see page 40).
Power Supply Troubleshooting
If a power supply’s AC and DC power indicator LEDs are not illuminated:
Check to be sure the power cord is completely plugged into the Epica DGX 32 and to the
power source.
If the AC and DC LEDs remain unilluminated, contact technical support (see page 40).
Caution: Do not remove a failed power supply until you have the replacement and are ready to
install it, unless directed to do so by technical support. The Epica DGX 32 enclosure is able to
operate normally with a failed RPS.
FIG. 20
Power-up splash screen in HyperTerminal
[1:Enclosure] AMX AutoPatch Epica DGX 32
Ready
Splash Screen
Summary of Contents for Epica DGX 32
Page 6: ...Contents iv Epica DGX 32 Instruction Manual ...
Page 12: ...Notices 6 Epica DGX 32 Instruction Manual ...
Page 50: ...Installation and Setup 44 Epica DGX 32 Instruction Manual ...
Page 56: ...Epica DGX 32 SC Optical Boards 50 Epica DGX 32 Instruction Manual ...
Page 60: ...Epica DGX 32 DVI Boards 54 Epica DGX 32 Instruction Manual ...
Page 98: ...NXB AP 1000 Interface Initial Setup by Network Admin 92 Epica DGX 32 Instruction Manual ...
Page 102: ...NXB AP 1000 Interface Controlling the Epica DGX 32 96 Epica DGX 32 Instruction Manual ...
Page 108: ...NXB AP 1000 Interface Additional Info for Network Admin 102 Epica DGX 32 Instruction Manual ...
Page 114: ...Appendix A EDID Programmer 108 Epica DGX 32 Instruction Manual ...
Page 126: ...Appendix B Managing Configuration Files 120 Epica DGX 32 Instruction Manual ...