Installation and Setup
36
Epica DGX 32 Instruction Manual
Indicator Lights at Startup
When the enclosure powers up, the indicator LEDs respond as follows:
* IOS (Initial Operating System) is the base layer operating system on AMX AutoPatch equipment. IOS performs
functions such as hosting higher level run-time software applications. When unexpected critical errors are
encountered within such hosted applications, system control of the equipment may be passed to the IOS layer
preventing normal system operation until the error is manually cleared. Please report all such errors to AMX
AutoPatch technical support (see page 40).
Important: If the indicator LEDs do not respond with a normal display as stated above, check power
connections, before contacting technical support (see page 40).
Important: When the system is powered down, be sure the indicator LEDs on the CPU are off and
the fans have stopped before reapplying power.
The system is ready to disconnect the factory default switch and to execute a test switch (see page 38) using
the control method of your choice.
TCP/IP Startup for NXB-AP-1000 Server Connection
If you have not already done so, attach the enclosure to a PC via the TCP/IP port (see
page 40).
Serial Control Device Startup
If you have not already done so, attach the serial control device to the enclosure (see page 27) and open the
control program.
AMX Control Devices
The Epica DGX 32 is compatible with a number of AMX control devices. For control programming
information, see the instruction manual for the specific interface.
Epica DGX 32 LED Indicators
LED
Indicates
Normal Display
Cautionary
Front
Power
System power
Constant green
Constant red: only
one power supply
is working
Rear –
Power
Supply
AC Power (
)
AC power present
Constant green
Not illuminated:
AC failure
DC Power (
)
DC power present
Constant green
Not illuminated:
DC failure
Temperature ( ) Power supply temperature
Not illuminated
Amber: power
supply is over
temperature
Rear –
CPU
Enc Link
• Green
• Amber
See page 23
• Speed status is either
100 Mbps (on)
or 10 Mbps (off)
• Activity between enclosures
• Constant green
or not illuminated
• Blinks amber with activity
Status
System status
Constant green during power
up, then blinking green at 1
second on/off intervals
Blinking red/green:
an exception has
been logged in IOS
(validation failure)
Blinking red: dropped
into IOS mode*
TCP/IP
• LED to left
• Link/Activity
• Speed
See page 40
• Active server connection
• Active link status with server
• Speed status is either
100 Mbps (on)
or 10 Mbps (off)
• Blinks green at 5 second
intervals (left of RJ-45)
• Blinks amber (left on RJ-45)
• Constant green or not
illuminated (right on RJ-45)
Summary of Contents for Epica DGX 32
Page 6: ...Contents iv Epica DGX 32 Instruction Manual ...
Page 12: ...Notices 6 Epica DGX 32 Instruction Manual ...
Page 50: ...Installation and Setup 44 Epica DGX 32 Instruction Manual ...
Page 56: ...Epica DGX 32 SC Optical Boards 50 Epica DGX 32 Instruction Manual ...
Page 60: ...Epica DGX 32 DVI Boards 54 Epica DGX 32 Instruction Manual ...
Page 98: ...NXB AP 1000 Interface Initial Setup by Network Admin 92 Epica DGX 32 Instruction Manual ...
Page 102: ...NXB AP 1000 Interface Controlling the Epica DGX 32 96 Epica DGX 32 Instruction Manual ...
Page 108: ...NXB AP 1000 Interface Additional Info for Network Admin 102 Epica DGX 32 Instruction Manual ...
Page 114: ...Appendix A EDID Programmer 108 Epica DGX 32 Instruction Manual ...
Page 126: ...Appendix B Managing Configuration Files 120 Epica DGX 32 Instruction Manual ...