FireFinder
™
Installation Commissioning & Operation
Page 23
6
Expanding the FACP with Compatible FireFinder
TM
Boards
L
Numbers in
Italic
are
Panel Add On Order Codes
Module / Function............................................... Order Codes
Max Number Off
•
16/16 Input / Output Board ............................................ (302-6720)
8 per Slave CPU
( SP1X: 159-0113, SP8X: 159-0051, SP16X: 159-0009 )
•
8 Way Relay Board ....................................................... (302-6760)
16 per Slave CPU
( SP1X: 159-0013, SP8X: 159-0013, SPX16X: 159-0015 )
•
16
Way
Input
Board
...................................................... (302-6770)
8
per
Slave
CPU
( SP1X: 159-114, SP8X: 159-0010, SP16X: 159-0011 )
•
Serial
Relay
Board
........................................................ (302-7320)
16 per Controller
( SP1X: 159-0079, SP8X: 159-0072, SP16X: 159-0072)
•
Fire Fan Module / Fire Fan Termination Board.............. (159-0103 H/W)
15 per Controller
( SP1X: 159-0103, SP8X:159-0104, SP16X: 159-0119 )
•
Fire Fan Module ( Loop Driven ) .................................... (159-0105)
•
General Indicator Card [ 32 Zone Alarm ] ...................... (85BRDGIBB)
* 16
( SP1X: 159-0106 )
* Configuration dependant
( SP8X: 159-0089, SP16X: 159-0120 )
•
General Indicator Card [ 16/16 Zone Alarm / Fault ] ...... (85BRDGIBB)
* 16
( SP1X: 159-0107)
* Configuration dependant
( SP8X: 159-0108, SP16X: 159-0121 )
•
General Indicator Card ( Amber LED’s ) ........................ SP1X: 159-0123, SP8X &16: 159-0124
•
Printer............................................................................. (TPUP-AT)
1 per Controller
( SP1X: 159-0084, SP8X: 159-0110 )
•
Sounder/Bell Controller Board 8 X 1A per Circuit .......... (302-7420)
8 per Controller
( SP1X, SP8X: 159-0071 )
•
Sounder/Bell Controller Board 4Volt free, 4x1Amp ....... (302-7421)
8 per Controller
( SP1X, SP8X: 150-0069 )
•
Agent Release Module / Agent Termination Board ....... (BRD25ARB-A)
8 per Controller
( SP1X:159-0099, SP8X: 159-0100, SP16X: 159-0117 )
•
Local Control Station (IP40) ........................................... (BRD25ARB-B)
4 per Termination Board
(N/A)
•
Expansion
Board
........................................................... (302-6880)
1 per Controller
( SP8X: 159-0112, SP16X: 159-0022 )
•
Expansion
Controller......................................................
(SP16X: 159-0077
)
3 per Node
( Rack: 159-0067 )
•
Occupant Warning System – EV20 ............................... Factory fit
•
Occupant Warning System – EV40 / 60 / 120 ............... Factory fit
•
Occupant Warning System – EV3000 ........................... Factory fit
•
Brigade
Devices ............................................................. Factory fit
Compatible Networking Devices
•
Network Interface Card ................................................. (302-7240)
1 per Controller
( SP1: 159-0053, SP8X: 159-116, SP16X: 159-0053 )
•
Controller Interface Card ............................................... (302-7250)
1 per Controller
( SP1X: 159-0054, SP8X: 159-0115, SP16X: 159-0054 )
•
LCD Repeater ( Supplied Complete ) ............................ (302-7200)
Note # 2
( 159-0044 )
☞
Note # 1 :
This comprises 4 on the Main Controller and 4 on the Expansion Board.
☞
Note # 2 :
Depends on the configuration and the number of Panels in the System.