CHAPTER 4: OPERATING INSTRUCTIONS
UNIFLOW
®
4 PULSED HEAT CONTROL
990-908
4-11
Section V: Operating Instructions
When the
SYSTEM READY
message displays after Power Up, the Control is ready for operation using
either of the following options:
Pre-Defined Reflow Profiles. For your convenience, you may quickly select a profile stored in
the Control that has been pre-defined for your most common reflow applications.
Direct Input. You may use the front panel controls to input the parameters for a reflow
application.
Pre-Defined Reflow Profiles
1.
Push the
PROFILE NUMBER
up/down keys until the profile you
want (
1
63
) is displayed on the LCD screen.
NOTE:
The PROFILE NUMBER
up/down keys are disabled
when any screen
other than
the graphic screen or data screen
displays on the LCD.
2.
Set the
HEAT/NO HEAT
switch to
HEAT
. The Control is now
ready to use.
Direct Input
CAUTION
You can accidentally overwrite (erase) an existing stored profile when using the front
panel controls. Before you start
Direct Input
, use the
PROFILE NUMBER
up/down
keys to select a profile number that is “blank” or “expendable” to prevent overwriting
a profile you want to keep.
1.
Set the
HEAT/NO HEAT
switch to
HEAT
. In this position, the
Control will deliver heating energy to the thermode when you
initiate the heating cycle.
Summary of Contents for UNIFLOW 4 REMOTE
Page 1: ...990 908 REV K PULSED HEAT CONTROL UNIFLOW 4 UNIFLOW 4 REMOTE OPERATION MANUAL ...
Page 18: ...UNIFLOW 4 PULSED HEAT CONTROL xviii 990 908 ...
Page 19: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 xix ...
Page 20: ...UNIFLOW 4 PULSED HEAT CONTROL xx 990 908 ...
Page 21: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 xxi ...
Page 26: ......
Page 36: ......
Page 50: ......
Page 96: ......
Page 106: ......