CHAPTER 2: INSTALLATION AND SETUP
UNIFLOW
®
4 PULSED HEAT CONTROL
990-908
2-7
1.
Locate the
TRANSFORMER
CONNECTOR
at the bottom of the
Control's rear panel.
2.
Align the
RED
dot on the
TRANSFORMER CABLE CONNECTOR
to
the
RED
dot on the
TRANSFORMER
CONNECTOR
.
3.
Once the
RED
dots are aligned, push the
cable into the transformer connector
until it stops, then twist slightly
counterclockwise
until the connectors
are secured together.
4.
To
prevent
electrical noise on the
thermocouple
, place the thermocouple
cable along side of the transformer
cable that goes between the
Transformer and Control.
NOTE:
To disconnect, twist the
TRANSFORMER CABLE CONNECTOR
slightly
clockwise
,
then un-plug the cable.