APPENDIX D: COMMUNICATION CODES
UNIFLOW
®
4 PULSED HEAT CONTROL
D-12
990-908
13
Bytes
Total
SYSTEM
“YR” Read
Read system values
0 Bytes
“YS” Set
HeadCoolValveStatus (0 = OFF, 1 = ON)
1 Byte
,
1
Byte
SolderCoolValveStatus (0 = OFF, 1 = ON)
1 Byte
,
1
Byte
FootSwResponseMode (0 = ABORT, 1 = LATCH)
1 Byte
,
1
Byte
BuzzerLoudness (00 – 99)
2 Bytes
,
1
Byte
BuzzerAtEnd (0 = OFF, 1 = ON)
1 Byte
,
1
Byte
Idle Temperature (0=ON, 1 = OFF)
1 Byte
,
1
Byte
SafetyTimerTime (00 – 99)
2 Bytes
,
1
Byte
ReleaseTimerTime (00 – 99)
2 Bytes
,
1
Byte
MaxTempLimit (300 – 999)
3 Bytes
,
1 Byte
Backlight Operation (0=AUTO, 1=ON)
1 Byte
,
1 Byte
Max Aux Temp Limit (300 – 999)
3 Byte
,
1
Byte
Max Idle Temp Limit (025 – 300)
3 Bytes
,
1
Byte
Aux Temp Line (0=OFF, 1=ON)
1 Bytes
,
1
Byte
Aux Temp Number (0=OFF, 1=ON)
1 Bytes
36
Bytes
Total
TEMP
“TR” Read
Read current temperature
0 Bytes
TYPE
“TY” Read
Software release number and version number
0 Bytes
GRAPH
“GR” Read
Graph data points
0 Bytes
This command returns all of the temperature data points from the start of firing to the end of reflow for the current
actual temperature graph.
Summary of Contents for UNIFLOW 4 REMOTE
Page 1: ...990 908 REV K PULSED HEAT CONTROL UNIFLOW 4 UNIFLOW 4 REMOTE OPERATION MANUAL ...
Page 18: ...UNIFLOW 4 PULSED HEAT CONTROL xviii 990 908 ...
Page 19: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 xix ...
Page 20: ...UNIFLOW 4 PULSED HEAT CONTROL xx 990 908 ...
Page 21: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 xxi ...
Page 26: ......
Page 36: ......
Page 50: ......
Page 96: ......
Page 106: ......