CHAPTER 4: OPERATING INSTRUCTIONS
UNIFLOW
®
4 PULSED HEAT CONTROL
4-2
990-908
Section II: Power Up
Powering Up
To turn the Control power ON, set the
circuit breaker/power switch on the rear
panel to the ON position. After one
introductory screen is displayed, the
GRAPH screen will display with the
SYSTEM READY
message.
NOTES:
If the EMO jumper plug is
not
installed as described in
Chapter 2, Installation and
Setup
, the LCD Screen will
display a message saying that
an emergency stop is in effect.
The Control will
not
operate until the jumper is installed.
If the Control has been setup with the Idle temperature on, the message
WARM UP IN
PROGRESS – PLEASE WAIT
will be displayed while the Control heats to the set Idle
Temperature. Once the Idle Temperature is reached, the
SYSTEM READY
message will be
displayed.