CHAPTER 3: USING PROGRAMMING FUNCTIONS
UNIFLOW
®
4 PULSED HEAT CONTROL
990-908
3-23
The
2
key will bring up the
RELAY 1
status option screen.
The
1
through
8
keys on the keypad set
the
RELAY 1
status options.
1.
BASEHEAT
: Relay is
OPEN/CLOSED
during baseheat
process cycle
2.
RISE1
: Relay is
OPEN/CLOSED
from point at which 50% of
RISE1
time has elapsed until the end of
RISE1.
< RELAY 1 >
1. BASEHEAT
2. RISE1
3. PREHEAT ON
4. RISE2
5. REFLOW
6. COOL1
7. END OF REFLOW
8. CYCLE PWR ALARM
9.
__
NOT ACTIVE
PAGE FOR MORE RELAY SETTINGS
Number
Select,
Page,
Graph
/
Data
3.
PREHEAT ON
: Relay is
OPEN/CLOSED
during preheat process cycle.
4.
RISE2
: Relay is
OPEN/CLOSED
from point at which 50% of RISE2 time has elapsed until the
end of RISE2.
5.
REFLOW
: Relay is
OPEN/CLOSED
from start of heating to
COOL1
if no Postheat cycle
otherwise
COOL2.
6.
COOL1:
Relay is
OPEN/CLOSED
when COOL1 temperature is reached
7.
END OF REFLOW
: Relay is
OPEN/CLOSED
when
COOL1
is reached if no Postheat cycle, otherwise
COOL2
.
8.
CYCLE PWR ALARM:
Relay is
OPEN/CLOSED
when a more severe alarm, as indicated by “Cycle
Power” text in the alarm message, occurs.
9.
NOT ACTIVE
: Relay is not active.
If the desired relay state is not on the first
Relay State screen, press the
key to
select the second relay screen.
The
1
through
8
keys on the keypad set
the
RELAY 1
status options.
1.
SYSTEM READY
: Relay is
OPEN/CLOSED
when the Control is
ready for reflow operation.
< RELAY 1 >
1. SYSTEM READY
2. HEAT ON
3. HEAD IS UP
4. ALARM
5. OUT OF LIMITS
6. CLEAN THERMODE
7. REPLACE THERMODE
8. IDLE HEAT
PAGE FOR MORE RELAY SETTINGS
Number
Select,
Page,
Graph
/
Data
2.
HEAT ON
: Relay is
OPEN/CLOSED
during baseheat, rise1, preheat,rise2, reflow and postheat
process cycle.
3.
HEAD IS UP
: Relay is
OPEN/CLOSED
when head is retracted. If process does not have a Postheat
stage, then relay switches to active at COOL1. If the process does have a Postheat stage, then relay
Summary of Contents for UNIFLOW 4 REMOTE
Page 1: ...990 908 REV K PULSED HEAT CONTROL UNIFLOW 4 UNIFLOW 4 REMOTE OPERATION MANUAL ...
Page 18: ...UNIFLOW 4 PULSED HEAT CONTROL xviii 990 908 ...
Page 19: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 xix ...
Page 20: ...UNIFLOW 4 PULSED HEAT CONTROL xx 990 908 ...
Page 21: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 xxi ...
Page 26: ......
Page 36: ......
Page 50: ......
Page 96: ......
Page 106: ......