CHAPTER 2: INSTALLATION AND SETUP
UNIFLOW
®
4 PULSED HEAT CONTROL
2-12
990-908
4.
Using the air-head manufacturer’s user manual for reference, connect the head air valve
solenoid cable connector to the Control
HEAD VALVE
connector.
NOTE:
This connector supplies 24 VDC or 24VAC power for the
standard version
, or
24VDC only for the
remote version
. It will
not
drive 115 VAC air valves.
5.
Connect a properly filtered air line to the air inlet fitting on the head. Use 0.25 inch O.D. by
0.17 inch I.D. plastic hose with a rated burst pressure of 250 psi. Limit the length of the air line
to less than 40 in. (1 m) or thermode motion will be very slow.
NOTE:
Use a lubricator
only
with automated installations.
6.
Turn on the air system and check for leaks.
7.
Set the
HEAT/NO HEAT
switch on the Control front panel to the
NO HEAT
position. In this
position, the Control can
not
deliver heating energy to the thermode, but it
will
automatically
control the head.
8.
Set the circuit breaker on the
rear panel of the Control to the
ON position. The default
graphic screen will display.
You will use this screen to enter
heating parameters.
9.
Turn the air regulator clockwise
to produce
10 psi
on the air
regulator pressure gauge.
10.
Press the foot switch down to close the first level, and hold the foot switch at the first level.
The thermode should descend to the parts.
11.
If the parts are properly positioned under the thermode, press the foot switch to the second
(bottom) level. The Control should begin a process cycle without applying heat and the
head should immediately retract. If the head
does
retract, go to Step 14. If the head does
not
retract, go to Step 13.
12.
Increase air pressure in
5 psi increments
and repeat Steps 11 and 12 until the thermode
automatically retracts at the end of the process cycle.
13.
Press the foot switch to actuate to the first level. The thermode should descend smoothly to
the surface of the parts. When it reaches the parts, release the foot switch and go to Step 16.
If it does not descend
smoothly
, go to Step 15.
14.
Adjust the head down speed control knob and repeat Step 14 until the thermode descends
smoothly.
Summary of Contents for UNIFLOW 4 REMOTE
Page 1: ...990 908 REV K PULSED HEAT CONTROL UNIFLOW 4 UNIFLOW 4 REMOTE OPERATION MANUAL ...
Page 18: ...UNIFLOW 4 PULSED HEAT CONTROL xviii 990 908 ...
Page 19: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 xix ...
Page 20: ...UNIFLOW 4 PULSED HEAT CONTROL xx 990 908 ...
Page 21: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 xxi ...
Page 26: ......
Page 36: ......
Page 50: ......
Page 96: ......
Page 106: ......