CHAPTER 3: USING PROGRAMMING FUNCTIONS
UNIFLOW
®
4 PULSED HEAT CONTROL
990-908
3-27
REFLOW SETUP
With the
SETUP MENU
screen displayed,
press the
3
key to bring up the
REFLOW
SETUP
screen.
< SETUP MENU >
1. HARDWARE SETUP
2. COMMUNICATIONS
3. REFLOW SETUP
4. SYSTEM SECURITY
5. COPY PROFILE
6. SET TO DEFAULTS
7. LANGUAGE
8. I/O STATUS
Number
Select an item,
Graph
/
Data
SET IDLE TEMPERATURE ON/OFF
Press the
1
key to toggle between
ON
and
OFF
. Selecting
ON
enables the
Idle
Temperature
value in the Profile. The
Idle temperature is set on the Schedule
Setup screen, Page 2 of 2
. Selecting
ON
forces the thermode temperature to
rise to the
Idle
temperature set in the
current Profile and to continuously stay
at the Idle temperature except during a
heating cycle. Selecting
OFF
turns off
the Idle temperature function no matter
< REFLOW TEMPERATURE SETUP >
1. IDLE TEMPERATURE IS
: OFF
2. SET SAFETY TIMER
: 10
SEC
3. SET RELEASE TIMER
: 00
SEC
4. MAX TEMPERATURE LIMIT
: 600
C
5. MAX AUX TEMPERATURE LIMIT
: 600
C
6. MAX IDLE TEMPERATURE LIMIT
: 300
C
7. DISPLAY AUX TEMP NUMBER
: OFF
8. DISPLAY AUX TEMP LINE
: OFF
Number
Select,
Page,
Graph
/
Data
what temperature value is set in the
current Profile.
SET SAFETY TIMER
Press the 2
key
to bring up the
SET
SAFETY TIMER SCREEN
. Use the safety
timer to abort the reflow cycle if
temperature has
not
risen to the
REFLOW
temperature set point by the time set in
the safety timer. The safety timer starts
timing at the beginning of
RISE2
. If the
time is exceeded, a
SAFETY TIME
EXCEEDED
alarm will be set.
< SET SAFETY TIMER >
SET SAFETY TIMER
: 00
After edit
Page to accept new value
Number
Change,
Adjust,
Graph
/
Data
Use the number or
keys
to select a safety timer value of 00 to 99 seconds.
Summary of Contents for UNIFLOW 4 REMOTE
Page 1: ...990 908 REV K PULSED HEAT CONTROL UNIFLOW 4 UNIFLOW 4 REMOTE OPERATION MANUAL ...
Page 18: ...UNIFLOW 4 PULSED HEAT CONTROL xviii 990 908 ...
Page 19: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 xix ...
Page 20: ...UNIFLOW 4 PULSED HEAT CONTROL xx 990 908 ...
Page 21: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 xxi ...
Page 26: ......
Page 36: ......
Page 50: ......
Page 96: ......
Page 106: ......