CHAPTER 2: INSTALLATION AND SETUP
UNIFLOW
®
4 PULSED HEAT CONTROL
2-8
990-908
Control to Head Connections
To connect the Control to the reflow soldering or heat seal head, refer to the head manufacturer’s
manual as you follow the instructions below.
1.
Connect the reflow soldering or heat seal head thermocouple cable, referenced in this manual
as
MAIN
thermocouple, to terminal block
J9
on the rear panel. Connect a second thermocouple,
referenced in this manual as
AUXILIARY
thermocouple, to terminal block
J15
on the rear panel.
2.
To reduce noise pickup,
make sure the thermocouple cables do
not
run next to the
transformer cables that connect the head to the transformer terminals on the remote
transformer. If you are using two individual thermocouple wires, they
must
be twisted
together in order to reduce noise pickup.
NOTES:
The connector is keyed so that it cannot be installed improperly.
The Control requires that the thermocouple polarity be correct. If the thermocouple
polarity is reversed, the control may display the error message “OVER POWER
ALARM – Check TC (thermocouple), Cycle Power.” See
Appendix B
, Main
Thermocouple Input Connector (J9) for the correct connection.
The Control will
not
respond to an initiation signal until the thermocouple is properly
connected. The LCD will display an error message if the thermocouple is not
connected.
3.
Plug the green
CONTROL INPUT JUMPER
plug (marked
P4B)
into connector
J4B
on the rear
panel.
4.
Connect the data interface connectors on the rear panel to the PLC using the Phoenix-type
connector, J6A/J6B.
5.
If you are working in a CE standards environment using an Emergency Stop Switch, it
must
be
connected across pins 1 and 2 of the
EMO SWITCH
connector. If you are
not
using an
Emergency Stop Switch, you
must
install the EMO jumper plug supplied in the Ship Kit on the
EMO SWITCH
connector. This plug shorts Pins 1 and 2, labeled
EMO SWITCH
on the rear panel.
See
Appendix B, Electrical and Data Connections
for details.
NOTE:
If the EMO jumper plug, or an Emergency Stop Switch, is
not
connected to pins 1 and
2, an
Emergency Stop Alarm
will be activated.
Summary of Contents for UNIFLOW 4 REMOTE
Page 1: ...990 908 REV K PULSED HEAT CONTROL UNIFLOW 4 UNIFLOW 4 REMOTE OPERATION MANUAL ...
Page 18: ...UNIFLOW 4 PULSED HEAT CONTROL xviii 990 908 ...
Page 19: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 xix ...
Page 20: ...UNIFLOW 4 PULSED HEAT CONTROL xx 990 908 ...
Page 21: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 xxi ...
Page 26: ......
Page 36: ......
Page 50: ......
Page 96: ......
Page 106: ......