CHAPTER 4: OPERATING INSTRUCTIONS
UNIFLOW
®
4 PULSED HEAT CONTROL
990-908
4-3
Section III: Graph and Data Screen Descriptions
Graph Screen Description
Graph Schedule Profile
A graphical representation of the
programmed temperature profile is
displayed in the upper left section of the
GRAPH
Screen.
A thin solid line represents the
programmed temperature profile with
temperature on the Y axis and time on the
X axis. The line extends from the start of
Baseheat through the end of the Reflow
process cycle.
A separate solid thin line also represents the expected temperature plot for the
Auxiliary
thermocouple.
This line begins at the start of Rise1 and ends at the end of the Reflow process cycle.
Graph Actual Temperature and
Envelope Limits
A bold solid line represents the actual
temperature as measured by the
Main
thermocouple.
A dashed solid line represents the actual
temperature as measured by the
Auxiliary
thermocouple. In the screen picture
shown to the right, the Auxiliary
thermocouple is plotted as a straight
horizontal line for illustrative purposes
only.
If the
Envelope
functions has been selected for the
Main
and/or
Auxiliary
temperatures in the
Schedule
Setup
, then thin dashed lines will be displayed which represent the envelope for
Rise1
,
Preheat
,
Rise2
, and
Reflow
.
Summary of Contents for UNIFLOW 4 REMOTE
Page 1: ...990 908 REV K PULSED HEAT CONTROL UNIFLOW 4 UNIFLOW 4 REMOTE OPERATION MANUAL ...
Page 18: ...UNIFLOW 4 PULSED HEAT CONTROL xviii 990 908 ...
Page 19: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 xix ...
Page 20: ...UNIFLOW 4 PULSED HEAT CONTROL xx 990 908 ...
Page 21: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 xxi ...
Page 26: ......
Page 36: ......
Page 50: ......
Page 96: ......
Page 106: ......