CHAPTER 3: USING PROGRAMMING FUNCTIONS
UNIFLOW
®
4 PULSED HEAT CONTROL
990-908
3-13
Pressing the
GRAPH
key when the
Schedule Setup, Page 4 of 5
, screen is
displayed will change the display to the
Schedule Setup, Page 5 of 5
. This screen
contains parameters for the
Auxiliary
thermocouple’s envelope settings.
Press the
1
key to toggle
PREHEAT
ENVELOPE LIMITS
to between
ON
and
OFF
.
If set to
ON,
then the Control will monitor
temperatures and trigger an
Out of Limits
and messages if the temperature at any
< SCHEDULE SETUP, Page 5 of 5 >
AUXILIARY THERMOCOUPLE
1. PREHEAT ENVELOPE LIMITS
: OFF
2. REFLOW ENVELOPE LIMITS
: OFF
3. PREHEAT HIGH TEMP LIMIT
: +050
C
4. PREHEAT HIGH TEMP LIMIT
: -050
C
5. REFLOW HIGH TEMP LIMIT
: +050
C
6. REFLOW LOW TEMP LIMIT
: -050
C
7. AUX START TEMPERATURE
: 025
C
8. AUX PREHEAT TEMPERATURE
: 025
C
9. AUX REFLOW TEMPERATURE
: 025
SEC
Number
Select,
Page,
Graph
/
Data
point is outside the user-set
Preheat
Envelope Limits
.
If set to
OFF,
the Control will
not
monitor or display any temperature envelopes for Preheat.
Press the
2
key to toggle
REFLOW ENVELOPE LIMITS
to between
ON
and
OFF
. If set to
ON,
then the
Control will monitor temperatures and trigger an
Out of Limits
if the temperature at any point is outside
the user-set Reflow Envelope Limits. If set to
OFF,
the Control will
not
monitor or display any
temperature envelopes for Reflow.
Press the
3
though
6
keys to set the Envelope Limits. These parameters allow you to set the upper
and lower envelope limits for the auxiliary thermocouple temperature. The numbers entered will be
the difference between the expected temperature of the Auxiliary thermocouple and the envelope
limit.
For example, if you want an envelope that is
50 °C greater than the expected Auxiliary thermocouple
temperature,
then you should enter
50 °C in the
REFLOW HIGH TEMP LIMIT
field.
You set the
expected Auxiliary thermocouple temperature by entering the parameters for the
AUX START
TEMPERATURE, AUX PREHEAT TEMPERATURE
and
AUX REFLOW TEMPERATURE
. Press the
7
though
9
keys to set these parameters. The
AUX START TEMPERATURE
is the expected Auxiliary
thermocouple temperature at the start of Rise1. If the Rise1 time has been set to 0 seconds, then any
entry for
AUX START TEMPERATURE
will be ignored by the Control.
The
AUX PREHEAT TEMPERATURE
is the expected Auxiliary thermocouple temperature during
Preheat. The
AUX REFLOW TEMPERATURE
is the expected Auxiliary thermocouple temperature
during Reflow.
NOTE:
The expected Auxiliary thermocouple temperature and its envelope will only be displayed if
DISPLAY AUX TEMP LINE
is set to
ON
on the
REFLOW TEMPERATURE SETUP
Screen
.
Summary of Contents for UNIFLOW 4 REMOTE
Page 1: ...990 908 REV K PULSED HEAT CONTROL UNIFLOW 4 UNIFLOW 4 REMOTE OPERATION MANUAL ...
Page 18: ...UNIFLOW 4 PULSED HEAT CONTROL xviii 990 908 ...
Page 19: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 xix ...
Page 20: ...UNIFLOW 4 PULSED HEAT CONTROL xx 990 908 ...
Page 21: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 xxi ...
Page 26: ......
Page 36: ......
Page 50: ......
Page 96: ......
Page 106: ......