Timing:
The force valve actuates when the first level of the foot switch is closed.
It automatically
de-activates when the
COOL1
temperature is reached if there is not a Postheat process
cycle, or after the Head Up Delay if there is a Postheat process cycle, or in the event of a
reflow alarm.
The head cool valve is user-programmable to be ON or OFF. It is independent of the
reflow process cycle. It is used to prevent the thermocouple holder from overheating.
The solder cool valve is user-programmable to be ON or OFF. If the Profile does not have
a Postheat process cycle, selecting
ON
will activate the solder cool valve starting at the end
of the
Reflow
period and de-activating when the thermode reaches either the
COOL1
,
PREHEAT
,
or
BASE
temperature which ever is lower. If the Profile does have a Postheat
process cycle, selecting
ON
will activate the solder cool valve starting at the end of the
Reflow period and de-activate the valve when the thermode reaches the COOL1
temperature. The solder cool valve will also activate at the end of
POSTHEAT
and de-
activate when the thermode temperature reaches either the
COOL2, PREHEAT
,
or
BASE
temperature which ever is lower. The solder cool valve is used to cool the hot thermode
quicker.
Summary of Contents for UNIFLOW 4 REMOTE
Page 1: ...990 908 REV K PULSED HEAT CONTROL UNIFLOW 4 UNIFLOW 4 REMOTE OPERATION MANUAL ...
Page 18: ...UNIFLOW 4 PULSED HEAT CONTROL xviii 990 908 ...
Page 19: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 xix ...
Page 20: ...UNIFLOW 4 PULSED HEAT CONTROL xx 990 908 ...
Page 21: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 xxi ...
Page 26: ......
Page 36: ......
Page 50: ......
Page 96: ......
Page 106: ......