CHAPTER 3: USING PROGRAMMING FUNCTIONS
UNIFLOW
®
4 PULSED HEAT CONTROL
3-20
990-908
SETUP Key
This key brings up the
SETUP MENU
screen.
The
SETUP MENU
screen provides a
menu of operating characteristics for the
Control.
< SETUP MENU >
1. HARDWARE SETUP
2. COMMUNICATIONS
3. REFLOW SETUP
4. SYSTEM SECURITY
5. COPY PROFILE
6. SET TO DEFAULTS
7. LANGUAGE
8. I/O STATUS
Number
Select an item,
Graph
/
Data
HARDWARE SETUP
Pressing
1
with the
SETUP MENU
screen
displayed will bring up the
HARDWARE
SETUP
screen.
< HARDWARE SETUP
1. HEAD COOL VALVE IS
: OFF
2. SOLDER COOL VALVE IS
: OFF
3. FOOTSWITCH RESPONSE MODE
: ABORT
4. LIST OF HARDWARE
5. BACKLIGHT OPERATION
: ON
6. BUZZER LOUDNESS
: 50%
7. END OF CYCLE BUZZER
: ON
8. SET OUTPUT RELAYS
Number
Select,
Page,
Graph
/
Data
HEAD COOL VALVE IS
Press the
1
key to toggle between
OFF
and
ON
. Selecting
ON
continuously activates the head cool
valve, which supplies drive power for a user-supplied air solenoid valve. The drive power is
connector-selectable at either 24 VAC or +24 VDC
NOTE:
If Idle Heat is turned
ON
, the head cool valve is automatically turned on. This valve
controls air to cool a hot thermode holder on a reflow solder or heat seal head. See
Appendix B,
Electrical and Data Connections
for connection details.
SOLDER COOL VALVE IS
Press the
2
key to toggle between
OFF
and
ON
. If the Profile does not have a Postheat process cycle,
selecting
ON
will activate the solder cool valve starting at the end of the
Reflow
period and de-
activating when the thermode reaches either the
COOL1, PREHEAT, or BASE
temperature which ever
is lower. If the Profile does have a Postheat process cycle, selecting
ON
will activate the solder cool
valve starting at the end of the Reflow period and de-activate the valve when the thermode reaches
the
COOL1
temperature.
Summary of Contents for UNIFLOW 4 REMOTE
Page 1: ...990 908 REV K PULSED HEAT CONTROL UNIFLOW 4 UNIFLOW 4 REMOTE OPERATION MANUAL ...
Page 18: ...UNIFLOW 4 PULSED HEAT CONTROL xviii 990 908 ...
Page 19: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 xix ...
Page 20: ...UNIFLOW 4 PULSED HEAT CONTROL xx 990 908 ...
Page 21: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 xxi ...
Page 26: ......
Page 36: ......
Page 50: ......
Page 96: ......
Page 106: ......