CHAPTER 3: USING PROGRAMMING FUNCTIONS
UNIFLOW
®
4 PULSED HEAT CONTROL
3-22
990-908
BUZZER LOUDNESS
Press the
6
key to bring up the
BUZZER
LOUDNESS
adjustment screen. With this
screen, you may adjust the loudness of
the end of cycle buzzer so that it may be
heard reliably against background noise.
<BUZZER LOUDNESS >
BUZZER LOUDNESS
: 50 %
0 10 20 30 40 50 60 70 80 90
◄►
Adjust ,
▲
Page,
Graph
/
Data
END OF CYCLE BUZZER
Press the
7
key to toggle between
OFF
and
ON
for the end of cycle buzzer. When you select the
ON
option, a buzzer will sound when the actual thermode temperature reaches the
Cool 1
temperature setting
if there is no Postheat stage. If there is a Postheat stage, the buzzer will sound at the
Cool 2
temperature
setting.
SET OUTPUT RELAYS
Press the
8
key to bring up the
RELAY
screen. The
RELAY
screen allows you to
select the Alarm for Status actuation
states or each relay.
< RELAY >
1. RELAY 1 : OPEN WHEN NOT ACTIVE
2. RELAY 2 : OPEN WHEN NOT ACTIVE
3. RELAY 3 : OPEN WHEN NOT ACTIVE
4. RELAY 4 : OPEN WHEN NOT ACTIVE
5. RELAY 5 : OPEN WHEN NOT ACTIVE
6. RELAY 6 : OPEN WHEN NOT ACTIVE
7. RELAY 7 : OPEN WHEN NOT ACTIVE
Number
Select,
Page,
Graph
/
Data
See
Appendix B, Electrical and Data Connections
for the relay contact pin assignments at Control Status
Connector
J6A
.
Press the
1
through
7
keys to bring up the
desired relay screen. For example, press
1
to bring up the
RELAY 1
screen.
Press the
1
key to toggle
SET RELAY
to
between
CLOSED
and
OPEN
.
< RELAY 1 >
1. SET RELAY TO
: CLOSED
2. WHEN
: NOT ACTIVE
Number
Select, Page,
Graph
/
Data
Summary of Contents for UNIFLOW 4 REMOTE
Page 1: ...990 908 REV K PULSED HEAT CONTROL UNIFLOW 4 UNIFLOW 4 REMOTE OPERATION MANUAL ...
Page 18: ...UNIFLOW 4 PULSED HEAT CONTROL xviii 990 908 ...
Page 19: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 xix ...
Page 20: ...UNIFLOW 4 PULSED HEAT CONTROL xx 990 908 ...
Page 21: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 xxi ...
Page 26: ......
Page 36: ......
Page 50: ......
Page 96: ......
Page 106: ......