CHAPTER 4: OPERATING INSTRUCTIONS
UNIFLOW
®
4 PULSED HEAT CONTROL
4-10
990-908
Section IV: Process Cycle Parameters
Temperature Setting Ranges:
Idle ...................................................................................................... 25° to 300°C
Base ................................................................................................... 25° to 300°C
Preheat ............................................................................................... 60° to 500°C
Reflow (default) ................................................................................. 60° to 600°C
Reflow (extended mode operation) ................................................... 60° to 999°C
Cool1 ................................................................................................. 25° to 300°C
Postheat .............................................................................................. 25° to 600°C
Cool2 ................................................................................................. 25° to 300°C
Maximum Temperature ................................................................... 300° to 999°C
Time Setting Ranges:
Base ............................................................................................ 0 to 99.9 seconds
Rise1 .......................................................................................... 0.0 to 9.9 seconds
Preheat ........................................................................................ 0 to 99.9 seconds
Rise2 .......................................................................................... 0.0 to 9.9 seconds
Reflow ..................................................................................... 0.1 to 99.9 seconds
Postheat ....................................................................................... 0 to 99.9 seconds
Process Cycle Steps (No Postheat)
Process Cycle Steps (With Postheat)
Summary of Contents for UNIFLOW 4 REMOTE
Page 1: ...990 908 REV K PULSED HEAT CONTROL UNIFLOW 4 UNIFLOW 4 REMOTE OPERATION MANUAL ...
Page 18: ...UNIFLOW 4 PULSED HEAT CONTROL xviii 990 908 ...
Page 19: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 xix ...
Page 20: ...UNIFLOW 4 PULSED HEAT CONTROL xx 990 908 ...
Page 21: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 xxi ...
Page 26: ......
Page 36: ......
Page 50: ......
Page 96: ......
Page 106: ......