APPENDIX B: ELECTRICAL AND DATA CONNECTIONS
UNIFLOW
®
4 PULSED HEAT CONTROL
B-20
990-908
EMERGENCY STOP Input
Switch
Rating:
48
VDC at 2 Amps minimum
Type of Switch:
Normally closed pushbutton
Timing:
When the
EMERGENCY STOP
switch is pressed, it removes 24-volt power
from
the
reflow
head,
causing it to retract immediately.
Manual Alarm Reset
Input Signal :
0 to 24 VDC
Timing:
By applying a signal at
J4A-7
, a PLC or external computer
can readily reset all alarms and out of limits conditions before proceeding with
the next reflow process.