1–2
Chapter 1: Cyclone IV Device Datasheet
Operating Conditions
December 2016
Altera Corporation
1
Cyclone IV E industrial devices I7 are offered with extended operating temperature
range.
Absolute Maximum Ratings
Absolute maximum ratings define the maximum operating conditions for Cyclone IV
devices. The values are based on experiments conducted with the device and
theoretical modeling of breakdown and damage mechanisms. The functional
operation of the device is not implied at these conditions.
lists the absolute
maximum ratings for Cyclone IV devices.
c
Conditions beyond those listed in
cause permanent damage to the device.
Additionally, device operation at the absolute maximum ratings for extended periods
of time have adverse effects on the device.
Maximum Allowed Overshoot or Undershoot Voltage
During transitions, input signals may overshoot to the voltage shown in
undershoot to –2.0 V for a magnitude of currents less than 100 mA and for periods
shorter than 20 ns.
lists the maximum allowed input overshoot voltage and
the duration of the overshoot voltage as a percentage over the lifetime of the device.
The maximum allowed overshoot duration is specified as a percentage of high-time
over the lifetime of the device.
Table 1–1. Absolute Maximum Ratings for Cyclone IV Devices
Symbol
Parameter
Min
Max
Unit
V
CCINT
Core voltage, PCI Express
(PCIe
) hard IP
block, and transceiver physical coding sublayer
(PCS) power supply
–0.5
1.8
V
V
CCA
Phase
-
locked loop (PLL) analog power supply
–0.5
3.75
V
V
CCD_PLL
PLL digital power supply
–0.5
1.8
V
V
CCIO
I/O banks power supply
–0.5
3.75
V
V
CC_CLKIN
Differential clock input pins power supply
–0.5
4.5
V
V
CCH_GXB
Transceiver output buffer power supply
–0.5
3.75
V
V
CCA_GXB
Transceiver physical medium attachment (PMA)
and auxiliary power supply
–0.5
3.75
V
V
CCL_GXB
Transceiver PMA and auxiliary power supply
–0.5
1.8
V
V
I
DC input voltage
–0.5
4.2
V
I
OUT
DC output current, per pin
–25
40
mA
T
STG
Storage temperature
–65
150
°C
T
J
Operating junction temperature
–40
125
°C
(1) Supply voltage specifications apply to voltage readings taken at the device pins with respect to ground, not at the
power supply.
Summary of Contents for Cyclone IV
Page 10: ...x Chapter Revision Dates Cyclone IV Device Handbook March 2016 Altera Corporation Volume 1...
Page 14: ...I 2 Section I Device Core Cyclone IV Device Handbook March 2016 Altera Corporation Volume 1...
Page 274: ...vi Contents Cyclone IV Device Handbook February 2015 Altera Corporation Volume 2...
Page 440: ...iv Contents Cyclone IV Device Handbook December 2016 Altera Corporation Volume 3...
Page 442: ...vi Chapter Revision Dates Cyclone IV Device Handbook December 2016 Altera Corporation Volume 3...
Page 446: ......