1–92
Chapter 1: Cyclone IV Transceivers Architecture
Transceiver Top-Level Port Lists
February 2015
Altera Corporation
Reset & Power
Down
gxb_powerdown
Input
Asynchronous signal
Transceiver block power down.
■
When asserted, all digital and analog circuitry in the PCS,
HSSI, CDR, and PCIe modules are powered down.
■
Asserting the
gxb_powerdown
signal does not power
down the
refclk
buffers.
tx_digitalreset
Input
Asynchronous signal.
The minimum pulse
width is two parallel
clock cycles.
Transmitter PCS reset.
■
When asserted, the transmitter PCS blocks are reset.
rx_analogreset
Input
Asynchronous signal.
The minimum pulse
width is two parallel
clock cycles.
Receiver PMA reset.
■
When asserted, analog circuitry in the receiver PMA block
is reset.
rx_digitalreset
Input
Asynchronous signal.
The minimum pulse
width is two parallel
clock cycles.
Receiver PCS reset.
■
When asserted, the receiver PCS blocks are reset.
Reconfiguration
reconfig_clk
Input
Clock signal
Dynamic reconfiguration clock.
■
Also used for offset cancellation except in PIPE mode.
■
For the supported frequency range for this clock, refer to
the
chapter.
reconfig_togxb
Input
Asynchronous signal
From the dynamic reconfiguration controller.
reconfig_fromgxb
Output Asynchronous signal
To the dynamic reconfiguration controller.
Calibration Block
cal_blk_clk
Input
Clock signal
Clock for the transceiver calibration block.
cal_blk_powerdown
Input
Asynchronous signal
Calibration block power down control.
Test Mode
rx_bistdone
Output Asynchronous signal
BIST or PRBS test completion indicator.
■
A high level during BIST test mode indicates the verifier
either receives complete pattern cycle or detects an error
and stays asserted until being reset using the
rx_digitalreset
port.
■
A high level during PRBS test mode indicates the verifier
receives complete pattern cycle and stays asserted until
being reset using the
rx_digitalreset
port.
rx_bisterr
Output Asynchronous signal
BIST or PRBS verifier error indicator
■
In BIST test mode, the signal stays asserted upon detecting
an error until being reset using the
rx_digitalreset
port.
■
In PRBS test mode, the signal asserts for a minimum of 3
rx_clkout
clock cycles upon detecting an error and
deasserts if the following PRBS sequence contains no error.
Table 1–29. Multipurpose PLL, General Purpose PLL and Miscellaneous Ports in ALTGX Megafunction for
Cyclone IV GX (Part 2 of 2)
Block
Port Name
Input/
Output
Clock Domain
Description
Summary of Contents for Cyclone IV
Page 10: ...x Chapter Revision Dates Cyclone IV Device Handbook March 2016 Altera Corporation Volume 1...
Page 14: ...I 2 Section I Device Core Cyclone IV Device Handbook March 2016 Altera Corporation Volume 1...
Page 274: ...vi Contents Cyclone IV Device Handbook February 2015 Altera Corporation Volume 2...
Page 440: ...iv Contents Cyclone IV Device Handbook December 2016 Altera Corporation Volume 3...
Page 442: ...vi Chapter Revision Dates Cyclone IV Device Handbook December 2016 Altera Corporation Volume 3...
Page 446: ......