Chapter 3: Cyclone IV Dynamic Reconfiguration
3–3
Dynamic Reconfiguration Controller Architecture
November 2011
Altera Corporation
shows a conceptual view of the dynamic reconfiguration controller
architecture. For a detailed description of the inputs and outputs of the
ALTGX_RECONFIG instance, refer to
“Error Indication During Dynamic
1
Only PMA reconfiguration mode supports manual equalization controls.
1
You can use one ALTGX_RECONFIG instance to control multiple transceiver blocks.
However, you cannot use multiple ALTGX_RECONFIG instances to control one
transceiver block.
Figure 3–1. Dynamic Reconfiguration Controller
Note to
(1) The PMA control ports consist of the V
OD
, pre-emphasis, DC gain, and manual equalization controls.
Offset
Cancellation
control logic
reconfig_address_out[5..0]
Channel
reconfig
logic
ALTGX_RECONFIG MegaWizard Plug-In Manager
ALTGX_RECONFIG Instance
(Dynamic Reconfiguration Controller)
reconfig_clk
read
write_all
PMA control ports
(1)
logical_channel_address[n..0]
rx_tx_duplex_sel[1..0]
reconfig_mode_sel[2..0]
reconfig_address_en
channel_reconfig_done
error
busy
data
v
alid
reconfig_togxb[3..0]
reconfig_fromgxb[n..0]
ALTGX MegaWizard
Plug-In Manager
ALTGX Instances
Parallel
to
Serial
Con
v
erter
addr
data
Address
Translation
Analog controls
reconfig logic
reset_reconfig_address
reconfig_data[15..0]
reconfig_reset
Summary of Contents for Cyclone IV
Page 10: ...x Chapter Revision Dates Cyclone IV Device Handbook March 2016 Altera Corporation Volume 1...
Page 14: ...I 2 Section I Device Core Cyclone IV Device Handbook March 2016 Altera Corporation Volume 1...
Page 274: ...vi Contents Cyclone IV Device Handbook February 2015 Altera Corporation Volume 2...
Page 440: ...iv Contents Cyclone IV Device Handbook December 2016 Altera Corporation Volume 3...
Page 442: ...vi Chapter Revision Dates Cyclone IV Device Handbook December 2016 Altera Corporation Volume 3...
Page 446: ......