Chapter 6: I/O Features in Cyclone IV Devices
6–33
High-Speed I/O Standards Support
March 2016
Altera Corporation
A resistor network is required to attenuate the output voltage swing to meet RSDS,
mini-LVDS, and PPDS specifications when using emulated transmitters. You can
modify the resistor network values to reduce power or improve the noise margin.
The resistor values chosen must satisfy
.
1
Altera recommends that you perform simulations using Cyclone IV devices IBIS
models to validate that custom resistor values meet the RSDS, mini-LVDS, or PPDS
requirements.
It is possible to use a single external resistor instead of using three resistors in the
resistor network for an RSDS interface, as shown in
. The external
single-resistor solution reduces the external resistor count while still achieving the
required signaling level for RSDS. However, the performance of the single-resistor
solution is lower than the performance with the three-resistor network.
shows the RSDS interface with a single resistor network on the top and
bottom I/O banks.
:
(1) R
S
and R
P
values are pending characterization.
Equation 6–1. Resistor Network
Figure 6–16. RSDS, Mini-LVDS, or PPDS Interface with External Resistor Network on the Top and
Bottom I/O Banks
(1)
R
S
R
P
2
-------
R
S
R
P
2
-------
+
--------------------
50
=
Figure 6–17. RSDS Interface with Single Resistor Network on the Top and Bottom I/O Banks
:
(1) R
P
value is pending characterization.
RSDS Recei
v
er
100
Ω
50
Ω
Cyclone IV Device
Single Resistor
N
et
w
ork
Emulated
RSDS Transmitter
R
P
50
Ω
Summary of Contents for Cyclone IV
Page 10: ...x Chapter Revision Dates Cyclone IV Device Handbook March 2016 Altera Corporation Volume 1...
Page 14: ...I 2 Section I Device Core Cyclone IV Device Handbook March 2016 Altera Corporation Volume 1...
Page 274: ...vi Contents Cyclone IV Device Handbook February 2015 Altera Corporation Volume 2...
Page 440: ...iv Contents Cyclone IV Device Handbook December 2016 Altera Corporation Volume 3...
Page 442: ...vi Chapter Revision Dates Cyclone IV Device Handbook December 2016 Altera Corporation Volume 3...
Page 446: ......