368
Agilent X-Series Signal Generators SCPI Command Reference
Digital Signal Interface Module Commands
Digital Subsystem—Option 003 and 004 ([:SOURce])
:DIGital:DATA:OUTPut:QOFFset
Supported
N5172B/82B with option 003
:DIGital:DATA:OUTPut:QOFFset <value>
:DIGital:DATA:OUTPut:QOFFset?
This command adjusts the DC offset for Q data. The command is available for the N5102A module
output mode. The variable
<value>
is expressed as a +/– 100% of the full scale value.
Example
:DIG:DATA:OUTP:QOFF 40
The preceding example sets the Q offset to 40% of full scale.
*RST
+0.00000
Range
–100 to 100
Key Entry
Q Offset
:DIGital:DATA:OUTPut:ROTation
Supported
N5172B/82B with option 003
:DIGital:DATA:OUTPut:ROTation <value>
:DIGital:DATA:OUTPut:ROTation?
This command rotates the IQ data in the IQ plane. This command is valid for the N5102A output
mode. The variable
<value>
is expressed in degrees with a range from 0 to 360.
Example
:DIG:DATA:OUTP:ROT 45
The preceding example rotates the IQ constellation 45 degrees.
*RST
+0.00000
Range
0 to 360
Key Entry
Rotation