250
Agilent X-Series Signal Generators SCPI Command Reference
Arb Commands
Dmodulation Subsystem–N5172B/82B with Option 431 ([:SOURce]:RADio:DMODulation:ARB)
Remarks
To change the current filter type, refer to
“:FILTer” on page 248
.
:FILTer:BBT
Supported
N5172B/82B with Option 431
[:SOURce]:RADio:DMODulation:ARB:FILTer:BBT <val>
[:SOURce]:RADio:DMODulation:ARB:FILTer:BBT?
This command changes the bandwidth–multiplied–by–bit–time (BbT) filter parameter.
The filter BbT value can be set to the minimum level (0.1), the maximum level (1), or in between by
using fractional numeric values (0.100 to 0.999).
*RST
+5.00000000E
001
Range
0.100 to 1.000
Key Entry
Filter BbT
Remarks
This command is effective only after choosing a Gaussian filter. It does not have
an effect on other types of filters.
To change the current filter type, refer to
“:FILTer” on page 248
.
:FILTer:CHANnel
Supported
N5172B/82B with Option 431
[:SOURce]:RADio:DMODulation:ARB:FILTer:CHANnel EVM|ACP
[:SOURce]:RADio:DMODulation:ARB:FILTer:CHANnel?
This command optimizes the Nyquist and Root Nyquist filters to minimize error vector magnitude
(EVM) or to minimize adjacent channel power (ACP).
EVM
This choice provides the most ideal passband.
ACP
This choice improves stopband rejection.
*RST
EVM
Key Entry
Optimize FIR For EVM ACP
Remarks
To change the current filter type, refer to
“:FILTer” on page 248
.
:HEADer:CLEar
Supported
N5172B/82B with Option 431
[:SOURce]:RADio:DMODulation:ARB:HEADer:CLEar
This command clears the header information from the file header used by this modulation format.
Key Entry
Clear Header
Remarks
The
Digital Modulation Off On
softkey must be set to On for this command to function.
:HEADer:SAVE
Supported
N5172B/82B with Option 431