1.2-03
Tabelle 1.7: Lebensdauer in Übereinstimmung mit IEC 60947
Tabella 1.7: Specifiche durata nominale versione AC/DC IEC 60947
BREAKER ME10
BREAKER
SPECIFICA
TION
1
.2
English
Deutsch
AG32,40 or AJ32,40
AG32,40 oder AJ32,40
Air Circuit Breaker Denomination ............. Leistungsschalter Varianten .........................................................................
CO operations
Wechselschaltungen
Electrical Endurance
Elektrische Lebensdauer
Envelope type .................................................... Baugrößen-Zugehörigkeit .............................................................................
For Endurance in DC applications please refer to the IEC 60947 .............................................................................
Für Lebensdauer in Gleichstromanwendungen
siehe IEC 60947
Mechanical Endurance
Mechanische Lebensdauer
Power Circuit Breaker type
Leistungsschalter Typ
Rated current In ................................................ Bemessungsstrom In .......................................................................................
With Maintenance
Mit Wartung
Without Maintenance .................................... Ohne Wartung .....................................................................................................
4) AG is the standard type (Single cluster drawout construction) ....................................................................................
4) AG ist der Standardtyp (Einzelanschluss)
4) AH is the limited de-rating version (Dual cluster drawout construction) .................................................................
4) AH: Version für höhe Betriebswerte (Doppelanschluss)
Italiano
AG32,40 o AJ32,40
Denominazione interruttore aperto
Manovre di chiusura/apertura
Durata elettrica
Taglia
Per la durata in applicazioni DC si rimanda alla
norma IEC 60947
Durata meccanica
Tipo interruttore aperto
Corrente nominale In
Con manutenzione
Senza manutenzione
4) AG è il tipo standard (singolo cluster esecuzione estraibile)
4) AH è la versione a declassamento limitato (doppio cluster
esecuzione estraibile)
Electrical Endurance
CO operations at 1000VAC
without maintenance
Electrical Endurance
CO operations at 440V AC
without maintenance
Electrical Endurance
CO operations at 690V AC
without maintenance
Envelope type
Mechanical Endurance
with maintenance
without maintenance
Power Circuit Breaker type
Air Circuit Breaker Denomination
Table 1.7: Endurance in accordance with EN 60947-2
1)
Rated current In
A at 50°C
(1) For Endurance in DC applications please refer to the IEC 60947.
(2) 2000A type 8000 CO operations
(3) 2000A type 6000 CO operations
(4) AG is the standard type (Single cluster drawout construction) ..and AH the limited de-rating version (Dual cluster drawout construction)
R
K
500
300
500
500
500
500
10000
(2)
10000 5000
6000
5000
5000
2500
1500
8000
(3)
5000
5000
2500
1500
1000
1
2
2
3
3
2
20000
12500
20000
10000
10000
5000
20000
10000
10000
5000
20000
10000
10000
5000
10000
5000
AG 04, 07, 08, 10, 13, 16 or 20
AG 25
AG 32, 40 or GH 32, 40
(4)
AG 50
S
N
N
N
H
H
H
E
M
M
M
G
L
400, 630, 800, 1000,
1250, 1600 or 2000
2500
3200 or 4000
6400
AG 64
M L
5000
3
10000
5000
1500
1000
AT 04,
07, 08, 10,
13, or 16
1000
400, 630,
800, 1000,
1250 or 1600
T
20000
12500
6000
M L
500