15
EKI-9500 Series User Manual
1.
Remove the protection cap from the power input.
Figure 2.5 Removing the Protection Cap
2.
Secure the power cable to the power input.
Figure 2.6 Installing the Power Cable
The power input is now connected to the switch. The switch can be powered on.
2.4.4.1
Standard M23 6-Pin Male Pin Assignment
This section describes the proper connection of the 12, 24, -48, 110, 125 and
250VDC to the DC power connector on the switch. The DC input connector is located
on the left side of the front panel. The power terminals are connected as shown in the
following figure. They are electrically floating inside the unit so that either may be
grounded by the user if desired. The chassis is earthened or ground (GND).
The mating connection to the switch is created through a RD24, female connector.
Simply align the keyed female connector to the male connector and twist the
threaded to secure.
Figure 2.7 Standard M23 6-Pin Male DC Power Input Connector
1
2
1
2
1
2
5
4
6
3