No grease draw-off
Control (14) without power supply
Restore power supply (electrician)
Automatic operation is switched off
Switch on automatic operation
Grease collecting barrel (30)' full
Change collecting barrel (30)
Grease not flowable
Check heating rod (28), replace if
necessary
"Solenoid valves" miniature circuit-breaker
has tripped
Switch miniature circuit breakers back on
again. In case of renewed tripping, check
the solenoid valve and/or pneumatic ball
valve and replace any defective parts
Pneumatic ball valve (29) does not open
Check function, replace defective parts if
necessary
No compressed air supply
Check compressor (18) and compressed
air hoses, replace any defective parts
Water level too low
Check the freshwater supply
No sludge draw-off
Control (14) without power supply
Restore power supply (electrician)
Automatic operation is switched off
Switch on automatic operation
Sludge collecting barrel (19) full
Change collecting barrel
"Solenoid valves" miniature circuit-breaker
has tripped
Switch miniature circuit breakers back on
again. In case of renewed tripping, check
the solenoid valve and/or pneumatic ball
valve and replace any defective parts
Pneumatic ball valve (20) does not open
Check function, replace defective parts if
necessary
No compressed air supply
Check compressor (18) and compressed
air hoses, replace any defective parts
Water level too low
Check the freshwater supply
Agitating device is
not running
Control (14) without power supply
Restore power supply (electrician)
Automatic operation is switched off
Switch on automatic operation
"Agitating device" miniature circuit-breaker
has tripped
Switch miniature circuit breakers back on
again. In case of renewed tripping, check
the agitating device (6) and replace any
defective parts
No heating
Control (14) without power supply
Restore power supply (electrician)
Automatic operation is switched off
Switch on automatic operation
"Heating" miniature circuit-breaker has
tripped
Switch miniature circuit breakers back on
again. In case of renewed tripping, check
the heating rod (28) and replace any
defective parts