Fig. 28 Correct Positioning
• Make sure that the lubricating roller does not get damaged against the screw when driving up the
platform for the first time.
• Slowly drive the platform upward while lubricating the screw.
• Adjust the position of the screw to the final limit switch at the top floor. The distance between this
screw and the top of the guide shoe is to be 10 mm when the platform is at the top level. See Fig. 29
Fig. 29 Positioning of the screw
• Adjust the locking arms when the platform is in the correct position on the top and bottom levels.
The wheel is to be positioned in the centre of the retiring ramp’s curve. See Fig. 30