6.8.3 SETTING LUBRICATION TIME
Factory default is 40% driving time. That is, oil is lubricating the screw 40% of the time. 40 % is a good
setting for normal conditions. Normal use is 20-30 rides per day with a lift installed inside. However is
the lift more frequently used or if the lift is outside in a warm or a cold climate the lubrication must be
adapted. High usage and high temperature = low settings Low usage and low temperature = high setting
Fig. 145 DIP switch setting for oil lubrication on U1 control board
DIP Switch settings
1:off2:off= 10%
1:on2:off= 20%
1:off2:on= 40%
1:on2:on= 80%
6.8.4 OIL PROTECTION COVER
After installation, the black plastic Oil protection cover needs to be checked. It shall be centred around,
and not touch, the screw.
If not, loosen the two lower nuts and adjust the cover. Before tightening the nuts, run the lift while ob-
serving the adjustment. When it´s centred, tighten the nuts. Do not tighten the nuts too hard, this can
damage the plastic cover.
7000 100 en-GB AD
123
Summary of Contents for 7000
Page 1: ...Vector Installation Manual HQ ...
Page 23: ...ASSEMBLY 5 ASSEMBLY 5 1 FIXINGS 7000 100 en GB AD 19 ...
Page 25: ...ASSEMBLY Fig 15 Mast preparation before installation 7000 100 en GB AD 21 ...
Page 27: ...ASSEMBLY Lift the top section 7000 100 en GB AD 23 ...
Page 33: ...ASSEMBLY 7000 100 en GB AD 29 ...
Page 34: ...ASSEMBLY 30 7000 100 en GB AD ...
Page 42: ...ASSEMBLY The mast shall stand upright the tolerance is Max 2 mm m 38 7000 100 en GB AD ...
Page 70: ...ASSEMBLY Fig 59 Mounting of Filled wall panels 66 7000 100 en GB AD ...
Page 72: ...ASSEMBLY Fig 61 Principal drawing Shaft corners 68 7000 100 en GB AD ...
Page 100: ...This page is intentionally left blank 96 7000 100 en GB AD ...
Page 117: ...OPTIONS Fig 126 Electrical connections external door opener 7000 100 en GB AD 113 ...
Page 140: ...This page is intentionally left blank 136 7000 100 en GB AD ...
Page 142: ...This page is intentionally left blank 138 7000 100 en GB AD ...