12
Continue to the “NGC Installation” instructions. Method of installation must be consistent
with customers company policy.
VIII.
NGC Installation
Once the mounting system has been installed inside the Cold Weather Enclosure, these
instructions should be followed to install the NGC onto the mounting pipe.
Before you begin, review the procedure and the materials required for installation.
A. Materials
•
Installed Mounting Pipe
•
4 ea. 5/16”Hex Socket Screws (Mounting Pipe with Flange kit option)
•
NGC
B. Instructions
1)
Position NGC on top of 2” pipe stand (see Figure 16), level in close
approximation to correct orientation.
2)
If installation has the Optional Mounting Pipe with Flange, ensure screw holes
in upper flange align with holes located in the NGC neck bottom (see Figure
17).
3)
Position unit on Pipe. The front display of the unit would normally face left,
with the Feed-Through Assembly facing the front opening of the enclosure.
This allows screen visibility, access to the Feed-Through Assembly and
Termination Panel located in the rear of the housing.
4)
Secure in place by tightening the Hex Socket Set Screw located in the neck
of the unit using a 1/8” Hex Wrench.
CWE
MOUNTING
PLATE
Figure 16 NGC Mounting