The format of the input assembly is:
The value of Input I/O 1 to 9 is read from the data word or drive
parameter defined by Input I/O Par 1 to 9 respectively. See
chapter
Drive configuration
.
Instance 103
Byte Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Input I/O 1 (Low Byte)
1
Input I/O 1 (High Byte)
2
Input I/O 2 (Low Byte)
3
Input I/O 2 (High Byte)
4
Input I/O 3 (Low Byte)
5
Input I/O 3 (High Byte)
6
Input I/O 4 (Low Byte)
7
Input I/O 4 (High Byte)
8
Input I/O 5 (Low Byte)
9
Input I/O 5 (High Byte)
10
Input I/O 6 (Low Byte)
11
Input I/O 6 (High Byte)
12
Input I/O 7 (Low Byte)
13
Input I/O 7 (High Byte)
14
Input I/O 8 (Low Byte)
15
Input I/O 8 (High Byte)
16
Input I/O 9 (Low Byte)
17
Input I/O 9 (High Byte)