04 HW/SW Option
Defines the selection source of module MacID and baud rate.
0
= selection of MAC ID and baud rate via the DIP switches
enabled.
1
= selection of MAC ID and baud rate via parameters 02 and 03
and via the DeviceNet Object enabled (see
section
DeviceNet
Object, Class 0x03
on page
64
)
.
05 Stop Function
Defines the method for stopping the motor with instances 20, 21
and 121.
0
= Ramp stop: the motor decelerates along the active
deceleration ramp.
1
= Coast stop: the motor comes to a stop by coasting.