![background image](http://html.mh-extra.com/html/abb/rdna-01/rdna-01_user-manual_206059.webp)
Communication
59
User Specific assembly
User Specific assembly allows the use of the ABB Drives
communication profile. The format of the output assembly is:
The value of Output I/O 1 to 9 sets the data word or drive
parameter defined by Output I/O Par 1 to 9 respectively. See
chapter
Drive configuration
.
Instance 102
Byte Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Output I/O 1 (Low Byte)
1
Output I/O 1 (High Byte)
2
Output I/O 2 (Low Byte)
3
Output I/O 2 (High Byte)
4
Output I/O 3 (Low Byte)
5
Output I/O 3 (High Byte)
6
Output I/O 4 (Low Byte)
7
Output I/O 4 (High Byte)
8
Output I/O 5 (Low Byte)
9
Output I/O 5 (High Byte)
10
Output I/O 6 (Low Byte)
11
Output I/O 6 (High Byte)
12
Output I/O 7 (Low Byte)
13
Output I/O 7 (High Byte)
14
Output I/O 8 (Low Byte)
15
Output I/O 8 (High Byte)
16
Output I/O 9 (Low Byte)
17
Output I/O 9 (High Byte)
Summary of Contents for RDNA-01
Page 1: ...ABB Drives User s Manual DeviceNet Adapter Module RDNA 01 ...
Page 2: ......
Page 4: ......
Page 6: ...Safety instructions 6 ...
Page 10: ...Table of contents 10 ...
Page 14: ...Introduction 14 ...
Page 30: ...Mechanical installation 30 ...
Page 52: ...Communication profiles 52 ...
Page 80: ...Diagnostics 80 ...
Page 84: ...Definitions and abbreviations 84 ...
Page 87: ......