Reconnecting the SMB and BU units
Note
Action
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the unit
read the safety information in section
1
Cover, electronics:
Check the electronic box gasket.
2
3HAC081189-003 (Graphite
White)
Replace if damaged.
3HAC081189-004 (ABB Orange)
xx2200001726
Connect all connectors to the SMB board:
•
R1.SMB1-3, R1.SMB4-6 and R2.SMB
•
If cabling is used for 7th axis (option), refit the
connector R1.SMB7
3
Connect the connectors R2.BU1 and R2.BU2 to the
brake release board.
4
Refitting the electronic box
Note
Action
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the unit
read the safety information in section
1
Torx pan head screw: M6x60 (4
pcs)
Refit the electronic box with the attachment screws.
2
Tightening torque: 10 Nm.
xx2200001721
Continues on next page
Product manual - IRB 6710
315
3HAC085695-001 Revision: A
© Copyright 2023 ABB. All rights reserved.