Refitting the cable harness - base, frame and lower arm
These procedures describes how to refit the cable harness in base, frame and
lower arm.
Preparations before refitting the cable harness
Use this procedure to understand the layout of the new cable harness spare part.
Note
Action
Floor-standing robot:
1
Lay the new cable harness on the floor, and place
the lower part around the manipulator to under-
stand the layout.
Refitting the cable harness in the lower arm
Note
Action
xx1300000668
Tip
Use tape and tie the axis-5 and axis-6
connectors and carrier into a bundle (if not
already done). This is done to facilitate the
procedure and to avoid damaging the parts
during the procedure.
This will also make it easier to run the cable
harness through the inside of the robot.
1
xx2300000053
Run the upper part of the cable harness
through the lower arm.
2
Continues on next page
310
Product manual - IRB 6710
3HAC085695-001 Revision: A
© Copyright 2023 ABB. All rights reserved.