
Check for contamination / lack of free space
Note
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the safeguarded space.
1
xx1300000423
Check that there are no obstacles inside the frame, that
could prevent the balancing device from moving freely.
Keep the areas around the balancing device clean and free
from objects, such as service tools.
2
Product manual - IRB 6710
105
3HAC085695-001 Revision: A
© Copyright 2023 ABB. All rights reserved.
4 Maintenance
4.3.2 Inspecting the balancing device
Continued
Summary of Contents for IRB 6710
Page 1: ...ROBOTICS Product manual IRB 6710 ...
Page 8: ...This page is intentionally left blank ...
Page 14: ...This page is intentionally left blank ...
Page 36: ...This page is intentionally left blank ...
Page 584: ...This page is intentionally left blank ...
Page 614: ...This page is intentionally left blank ...
Page 634: ...This page is intentionally left blank ...
Page 639: ......