Removing cable harness in frame
Use this procedure to remove the cable harness in the frame.
Tip
Before starting this procedure, first remove the cable harness in the base. See
Removing the complete cable harness on page 195
.
Note
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot
working area.
1
How to remove the motor cables is de-
scribed in section:
•
Disconnect the
motor cables
on the axis-1
and axis-2 motors.
2
See the figure in:
•
Location of the cable harness on
page 196
Remove the
bracket
securing the cable
package to the frame.
3
See the figure in:
•
Location of the cable harness on
page 196
Cut the
cable straps
securing the cable
harness to the frame and lower arm.
4
A
C
E
F
B
D
xx1200000886
A Tape
B Connectors to SMB unit and Brake
release unit
C R1.CP/CS
D Air hose
E R1.MP
F R1.SMB (Connector bent and taped
upwards)
Prepare the end of the cable package in the
base with tape as shown in the figure.
Tip
In order to protect the connectors from
getting residual grease on the cable har-
ness, put some plastic over them prior to
pushing it through the hole in the frame.
5
Continues on next page
3HAC033453-001 Revision: H
203
© Copyright 2009-2013 ABB. All rights reserved.
4 Repair
4.3.1 Removing the complete cable harness
Continued
Summary of Contents for IRB 4600 - 20/2.50