Note
Action
xx0800000335
Refit the
bracket
on the
tubular shaft unit
.
12
Parts:
•
A: Tubular shaft unit
•
B: Attachment screws M6x16 qual-
ity 8.8-A2F (2 pcs)
•
C: Bracket
Refit the
signal lamp
, if used.
13
Calibration is detailed in a separate calib-
ration manual enclosed with the calibra-
tion tools.
Recalibrate the robot.
14
General calibration information is included
in section
DANGER
Make sure all safety requirements are met
when performing the first test run. These
are further detailed in the section
- First test run may cause injury or damage!
on page 50
.
15
250
3HAC033453-001 Revision: H
© Copyright 2009-2013 ABB. All rights reserved.
4 Repair
4.4.1 Replacing the complete upper arm
Continued
Summary of Contents for IRB 4600 - 20/2.50