Removing SMB battery
Use this procedure to remove the SMB battery.
Note
Action
This is done in order to facilitate
the updating of the revolution
counter.
Move the robot to its calibration position.
1
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot working area.
2
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit please read the safety information in the section
WARNING - The unit is sensitive to ESD! on page 53
3
See the figure in
Remove the
SMB battery cover
.
4
See the figure in
Pull out the
SMB battery
.
5
See the figure in
Disconnect the
battery cable
and remove the bat-
tery.
6
How to dispose of the used SMB battery, see
chapter
7
Refitting SMB battery
Use this procedure to refit the SMB battery.
Note
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot working area.
1
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit please read the safety information in the section
WARNING - The unit is sensitive to ESD! on page 53
2
See the figure in
Reconnect the
battery cable
to the
SMB battery
.
3
Continues on next page
3HAC033453-001 Revision: H
185
© Copyright 2009-2013 ABB. All rights reserved.
3 Maintenance
3.4.8 Replacing SMB battery
Continued